Solutions

PdM Solutions

Edge Gateway M4

Edge Gateway M4 connects Modbus, analog, LoRaWAN, vibration, and electrical-signature sources in minutes, then serves local browser dashboards and on-device history without cloud fees or installed client software.

  • All-in-one edge gateway for sensor visualization and local historian storage
  • Zero-code browser configuration for local or remote access
  • Drag-and-drop dashboard pages with charts, gauges, KPIs, and plant layouts
  • On-premises-first architecture with no cloud or monthly platform fees
  • Multi-sensor rollout for machine dashboards, facility KPIs, condition monitoring, and energy monitoring

Supported protocols

Connects to common industrial systems.

  • OPC UA
  • MQTT
  • GraphQL API
  • CSV
  • Google Sheets
  • Modbus RTU/TCP

Pricing

€1,699.00

I/O & Connectivity

Connect industrial sensors and plant data sources

The M4 gateway brings wired and wireless condition-monitoring data into one edge system for dashboards, history, and enterprise handoff.

  • Modbus RTU/TCP over RS-485 and Ethernet
  • Analog 4-20 mA loop and 0-10 V sensor inputs
  • Private LoRaWAN with built-in LNS and application server
  • Wireless full-spectrum vibration and electrical-signature sensing via FSK

Visualization

Build dashboards directly from a browser

Operators can create dashboard pages without code, place live gauges on uploaded layouts, and combine graphs and KPIs from sensor or data sources.

  • Drag-and-drop dashboard pages
  • Live gauges on uploaded machine or facility layouts
  • Graphs and KPIs from sensor and data-source values
  • Browser access for on-premises and remote users

Historian & Data Access

Keep high-resolution history on the device

The embedded historian stores sensor and Modbus time-series data locally while exposing direct interfaces for automation, analytics, and reporting.

  • High-resolution time-series database for sensor and Modbus data
  • Local storage on the gateway internal memory
  • Direct queries through OPC UA, MQTT, and GraphQL API
  • CSV and Google Sheets export paths

Manageability

Configure and maintain deployments without code

The gateway is designed for scalable field setup with browser-based configuration, OTA support, and fast device enablement through the I/O plugin.

  • OTA updates for current device support
  • Fast I/O plugin for rapid device enablement
  • Zero-code web UI for gateway configuration
  • Multi-sensor setup in minutes for repeatable rollouts

Specifications

Edge Gateway M4 specifications

System

SoC
Raspberry Pi CM4
RTC
NXP PCF8563 I2C Real-time Clock (CR1220 Backup)
Storage
32 GB eMMC 5.1; Peak 100 MB/s

Power

Input
8-28V DC
Max power
18 W
Connector
DC barrel jack, Center +
Indicator
Red PWR, Green ACT
Included PSU
Mean Well HDR-30-24 - 24V DC, 1.5A, 36W (DIN Rail); Class II, SELV/LPS

Ethernet

Interface
1x 10/100/1000Mbps RJ45
Services
Modbus TCP, DHCP server

Wi-Fi

2.4 GHz
IEEE 802.11 b/g/n
5 GHz
IEEE 802.11 a/n/ac
Antenna
External Dual-band 2 dBi (L=108 mm)

USB

Ports
2x USB-A

LoRa Gateway

Sensor Link
LoRa-FSK; LoRaWAN
Frequency plans
EU868, US915, AS923, IN867, AU915, KR920
Antenna
External 2 dBi (L=195 mm)

RS485

Ports
4x 3-pin, pitch 2.5 mm; Modbus RTU

Software

OPC UA
OPC UA Server + browser
MQTT
MQTT Client
API
GraphQL API Server
Embedded Web Interface
Sensor Monitoring; Analytics
Dashboard
Widget-based Studio
VPN
Hamachi; WireGuard
AI Anomaly Monitor
Requires optional AI Anomaly Detection Service

Compliance

FCC
47 CFR Part 15 Subpart B
CE
Scope: Edge Server hardware
EN IEC 62368-1
Product safety
EN IEC 62311
RF exposure
EN IEC 61000-3-2
Harmonics limits
EN IEC 61000-3-3
Flicker limits
EN 55032 (CISPR 32)
EMI multimedia
EN 55035 (CISPR 35)
EMC immunity
EN 301 489-1
EMC common
EN 301 489-3
EMC SRD
EN 301 489-17
EMC WLAN/BT
EN 301 489-52
EMC LTE/5G
EN 301 328
2.4 GHz radio
EN 300 440
SRD 1-40 GHz
EN 301 511
GSM radio
EN 301 908-1
Cellular common
EN 301 908-2
Cellular UTRA

Environment

Mounting
DIN rail 35 mm
IP degree
IP20 (IEC 529), indoor only
Operating temperature
-20 °C ... +60 °C
Humidity
5-95 % RH, non-condensing

Dimensions

Size
102 x 73 x 36 mm (excl. external Wi-Fi antenna and DIN-rail bracket)
Weight
500 g
Enclosure
Aluminum, ABS

Next step

Talk with Reshenie about Edge Gateway M4

Share your training, monitoring, or predictive maintenance requirements and we can map the right product configuration to your environment.